College of Physical Sciences
Permanent URI for this collectionhttps://ir.funaab.edu.ng/handle/123456789/256
Browse
Browsing College of Physical Sciences by Title
Now showing 1 - 20 of 66
- Results Per Page
- Sort Options
Item A BAYESIAN DESIGN-BASED GENERALIZED LINEAR MIXED MODEL FOR TWO-STAGE SURVEY DATA(2025-11-25) OLAKIIGBE, ABIODUNKANMIItem A COMPUTATIONAL STUDY OF HEAT AND MASS TRANSFER IN POWER LAW FLUID PAST AN ACCELERATED RIGA PLATE(2025-10-16) ADEYEMI, AMOO AZEEZItem A COMPUTATIONAL STUDY OF HEAT AND MASS TRANSFER IN POWER LAW FLUID PAST AN ACCELERATED RIGA PLAT(2025-10-20) ADEYEM1.AMOO AZEEZItem A NOVEL GLUCOSE BIOSENSOR BASED ON SILVER NANOPARTICLE (AgNP) STABILIZED WITH SODIUM TRIPOLYPHOSPHATE (NaTPP) CROSS-LINKED CHITOSAN: DIRECT ELECTRON TRANSFER AND ELECTROCATALYTIC ACTIVITY(2024-09-15) BAMIGBADE, Akeem AdesinaAbstract The development of non-enzymatic glucose biosensor has been the concern of many researchers mainly because enzymes based sensor despite having excellent sensitivity and selectivity, has the limitations such as poor stability, complicated enzyme immobilization, critical operating conditions such as optimum temperature and reproducibility, which hinder the sensor properties. The prevalence of renal problem globally justifies the need for the development of non-enzymatic glucose biosensor that can effectively and accurately detect glucose in any medium which can be very effective to the detection and treatment of diabetes mellitus. This study has developed a biocompatible non-enzymatic glucose biosensor, Direct electron transfer and electro-catalytic activity of non-enzymatic glucose biosensor based on silver nanoparticle (AgNPs) stabilized with sodium tripolyphosphate (NaTPP) cross-linked chitosan was studied. Silver nanoparticle was prepared and characterized by Fourier transform Infra-red spectroscopy (FTIR), X-ray diffractometry (XRD) and Scanning electron microscopy (SEM). The electro-catalytic activity of the synthesised AgNPs was investigated through potentiometric and amperometric techniques. The crystalline size of the AgNPs was revealed with XRD. The cubic face-centered structure of the synthesised silver nanoparticle was confirmed. This was supported by the observed sharp four diffraction peaks with peaks intense appearing at 2θ = 38.09°, 44.15°, 64.67°, and 77.54°. However, the SEM micrograph of the synthesised AgNPs revealed the spherical shape of AgNPs with a non-uniform granular shape attributed to bio-mediated ionic gelation process. The surface of the synthesised AgNPs has a spherical shape and slightly elongated with a big tendency to aggregate and form larger particle clusters. Whereas, FTIR spectra of AgNPs gave peaks at 1054 – 1645 cm-1 suggesting the presence of phosphonate linkages between ammonium, -NH3+ of chitosan and –PO32- moieties of NaTPP during cross linking process. The electro-catalytic oxidation of glucose at the electrode surface was examined and the mechanism involved in glucose oxidation was revealed. The silver nanoparticle modified glassy carbon electrode (AgNPGCE) showed a better electrochemical response towards glucose. This glucose sensor shows high sensitivity at +0.54 V. A low detection limit of 1.22 M taken the confident level to be 3, and wide linear range of 2 to 24 M with a correlation coefficient of 0.9987 were obtained. The calculated parameters revealed that AgNPs has shown better overall electrochemical performance with a response which is better than enzymatic biosensor. The fabricated AgNPs sensor shows comparable sensitivity (98%) of the initial value after it was kept in air for 8 days, demonstrating the very good sensitivity and durability of the glucose sensing. The good adhesion towards electrode and structural stability of AgNPs could be ascribed to long-term stability of AgNPs sensor. Based on these results, the AgNPGCE is a promising glucose biosensor candidate for excellent determination of glucose level in any medium.Item A SECURITY MANAGEMENT SYSTEM FOR CRITICAL INFORMATION INFRASTRUCTURE(2023-08-20) Adejimi, Alaba OlusesiItem ADAPTIVE HANDOFF PRIORITIZATION SCHEME FOR CONGESTION CONTROL IN MOBILE NETWORKS(2023-01-20) UGEGE, PETER EDEMEWEItem AN INTELLIGENT QUERY EXPANSION MODEL FOR IMPROVING QUALITY OF INFORMATION RETRIEVAL SYSTEMS(2024-06-30) ABASS, O. A.Item AN OPTIMIZED PERSONALITY RECOGNITION MODEL FOR SOCIAL MEDIA USERS(2025-06-15) ADEBIYI, BUKOLA TAIBATItem AN OPTIMIZED SERVERS' CONTROL AND CONGESTION AVOIDANCE MODEL FOR QUEUE NETWORK(2024-11-25) GBADEBO, ADEGBUYI DAVIDABSTRACT Researches on optimal control of servers in queue networks are enormous in literature but none of these had considered congestion control and servers' optimality concurrently. Since congestion control is a major factor in queue network management, the need to maintain a balance between servers' optimality and congestion control had become necessary. This study proposed a Fuzzy-Treap Based Servers' Optimal Control System (FTBSOCS) which is a dual model comprising of a fuzzy-based system and a Treap-based system implemented to minimize cost of servers' usage and customers’ losses due to congestion. Fuzzy logic was adopted to ensure optimal usage of available servers by applying a fuzzy rule-based method. This method was used to derive a fuzzified decision index which determined servers' deployment pattern. The Treap-based system was used to prevent network congestion by ensuring that customers arriving the queue network when it is saturated are managed to avoid dropping or starvation by transmitting them to a tree manager, from where they are re-transmitted for service upon the availability of an idle server. The FTBSOCS was benchmarked with Adaptive-Network-Based Fuzzy Inference System (ANFIS), ANFIS-M/M/α and ANFIS-Treap. OMNeT++ was used as the simulation framework while dataset were randomly generated which served as input to the methods. With the inclusion of fuzzy logic in FTBSOCS, results indicated that average servers’ deployment was 21, 19, 15 and 16 for ANFIS, ANFIS-Treap, FTBSOCS and ANFIS-M/M/α respectively when there were 12K, 24K, 36K, 48K and 60K customers in the network. This implied that the inclusion of fuzzy logic in FTBSOCS had minimized servers’ deployment. The average of percentage utilization of available servers was 21.6%, 18.4%, 17.2% and 15.3% for FTBSOCS, ANFIS, ANFIS-M/M/α and ANFIS-Treap respectively with 12K, 24K, 36K, 48K and 60K customers in the network, indicating that FTBSOCS optimizes servers’ usage than the other methods. The average network throughput was 63.7Mbps, 63.4Mbps, 59.2 Mbps and 52.6 Mbps for ANFIS-M/M/α, FTBSOCS, ANFIS-Treap and ANFIS respectively with 12K, 24K, 36K, 48K and 60K customers in the network. This shows that ANFIS-M/M/α had a comparative performance of < 0.5% over FTBSOCS while a comparative performance of 2.9% and 4.2% existed for FTBSOCS over ANFIS-Treap and ANFIS respectively. The average number of customers dropped was approximately 204kb, 185kb, 165kb and 17kb for ANFIS, ANFIS-Treap, ANFIS-M/M/α and FTBSOCS respectively with 12K, 24K, 36K and 48K customers in the network indicating that FTBSOCS had < 2% of the overall number of customers’ dropped. The average propagation delay was 29.5, 26.3, 13.4 and 13.3 nanoseconds for ANFIS-M/M/α, ANFIS-Treap, FTBSOCS and ANFIS respectively with 12K, 24K, 36K, 48K and 60K customers in the network. This indicated that FTBSOCS had a slightly worse performance of < 0.3% to ANFIS while FTBSOCS had a comparative performance of about 10.8% and 13.4% over ANFISM/M/α and ANFIS-Treap respectively. With these results, it was concluded that FTBSOCS was more optimal in the control of servers and congestion in queue network.Item AN OPTIMIZED SERVERS' CONTROL AND CONGESTION AVOIDANCE MODEL FOR QUEUE NETWORK SYSTEM(2025-05-20) GBADEBO, ADEGBUYI DAVIDItem ASSESSMENT OF CONTAMINATION EFFECT OF LIVESTOCK WASTE ON SURFACE AND GROUNDWATER USING INTEGRATED GEOPHYSICAL AND GEOCHEMICAL METHODS(2024-11-20) LASISI, RASAQ AKANJIABSTRACT Cattle confinement causes significant amount of animal wastes in the surface and subsoil, contributing an enormous amount of pollutant into the soil and nearby aquifer units. In order to evaluate the degree of pollution, the extent of migration of leachate formed from animal wastes and its impact on shallow aquifer unit should be appraised. In view of this, electrical resistivity survey (1D vertical electrical sounding (VES) and 2D electrical resistivity Tomography (ERT)) and geochemical methods were utilized on the study site and nearby water sources respectively. Apparent resistivity data were measured along sixteen profiles using Schlumberger and Wenner configuration while soil samples were collected from laid transverses at depths of 0-30 cm and 30-60cm respectively. Geochemical assessment of surface and groundwater samples were carried out according to standard laboratory practices while hydrochemical facies of the sampled water was evaluated using Piper Trilinear software. The VES, 2D and 3D resistivity data were processed and inverted using WINRESIST, RES2DINV and RES3DINV software respectively. The ranges of resistivity and thickness of the Topsoil, Silt Fine Sand layer and Clay layers according to VES are (3.2-54.80 Ωm, 0.4-3.4 m), (5 - 75Ωm, 0.2 -19.1 m), (4.6 -188.7 Ωm, 2.7 -12.7 m). The inverse resisting model section of the subsurface from 2D and 3D imaging revealed low resistivity value less than 10 Ωm suspected to be leachate infiltration while 3D inverse section allowed delineation of animal waste plume, weathered layer and seepage path. The extent of migration was up to a depth of about 9m and more pronounced in the south eastern part of the study site. Hence, possible contamination of shallow groundwater system as livestock market ages. All the collected soil sample along the traverse lines belong to sandy loam, moderately acidic with nitrate and moisture content value ranging from 9.87-135.39 mg/kg and 0.238 to 0.324 cm3/cm3, respectively, At selected soil depths. The result of the physicochemical analysis revealed that 77% of water samples to be within the permissible limits of WHO/NSDWQ for drinking purpose besides their suitability for irrigation use. Interpretation of the piper diagram showed NaHCo3 to be the dominant facies in the area while alkaline earth metal (Ca2+ x mg2+) and weak acid (HCo3-, Co3-) are dominant cation and anions in the area. Surface and groundwater in the study area are of fresh and alkaline water type.Item CHARACTERISATION OF ORGANIC MARKERS, HEAVY METALS, AND THEIR HEALTH RISK ASSESSMENT IN SELECTED INDUSTRIES IN SOUTH WESTERN STATES OF NIGERIA(2024-10-15) ARIFALO KIKELOMO MABINUOLAItem CHARACTERIZATION AND POTENTIAL UTILISATION OF NIGERIA GROWN Adansonia digitata (BAOBAB) FRUIT COMPONENTS(2023-08-25) ABORODE TAOFEEK OYENIYIItem CHARACTERIZATION OF AQUIFER FOR WATER SUPPLY TO CULTIVATED FARMLAND IN A BASEMENT COMPLEX USING ELECTRICAL RESISTIVITY METHOD ON DUFARMS AT FEDERAL UNIVERSITY OF AGRTICULTURE ABEOKUTA NIGERIA(2025-06-23) OLADODU IYANUOLUWAOLUWATOBILOBAABSTRACT This study aims to characterize aquifer systems within a crystalline Basement Complex terrain to enhance groundwater supply for cultivated farmland, using the 1D Electrical Resistivity Method. The investigation was conducted at DUFARMS ASSETRISE LIMITED FARM, located within the Federal University of Agriculture, Abeokuta (FUNAAB), Ogun State, Nigeria, where agriculture is critically dependent on groundwater due to irregular and seasonal rainfall patterns. The geophysical technique adopted was Vertical Electrical Sounding (VES) using the Schlumberger electrode configuration. A total of 24 VES points were surveyed across different sections of the farmland to assess the subsurface lithology and aquifer potential. Field data were processed and interpreted using IP2WIN and WinResist software packages, generating one-dimensional resistivity models for each sounding point. The interpretation revealed a stratified subsurface composed of topsoil, weathered basement, fractured basement zones, and fresh basement rock. The topsoil layer showed resistivity values ranging from 48 to 320 Ω•m, with an average thickness of 0.6 to 2.2 meters, indicating variations in soil composition (sandy, lateritic, or loamy) across the site. Beneath this layer, the weathered basement exhibited resistivity values between 20 and 90 Ω•m, with thicknesses ranging from 3.5 to 15.6 meters—a zone often saturated and serving as a primary aquifer unit. In some locations, fractured basement zones were identified with moderately low resistivity values (typically less than 60 Ω•m), indicating secondary porosity and groundwater storage potential. The dominant curve types encountered include H-type, KH-type, HA-type, and QH-type curves. The H and KH types were most prevalent, indicating a common geoelectric sequence of a relatively resistive topsoil underlain by a more conductive weathered or saturated zone, followed by a resistive fresh basement. These curve types are diagnostic of aquifer-bearing formations within basement terrains. The study identifies the second and third geoelectric layers—corresponding to the weathered and fractured basement zones—as the principal aquiferous units. These layers are potential targets for hand-dug wells, boreholes, or small-scale irrigation schemes. In conclusion, the 1D resistivity method has proven to be a reliable, non-invasive, and cost-effective approach for delineating groundwater-bearing formations in crystalline basement settings. The findings offer valuable guidance for irrigation planning, sustainable water resource management, and borehole siting on the DUFARMS farmland and similar agricultural projects in southwestern Nigeria.Item CHARACTERIZATION OF AQUIFER FOR WATER SUPPLY TO CULTIVATED FARMLAND IN A BASEMENT COMPLEX USING ELECTRICAL RESISTIVITY METHOD ON DUFARMS AT FEDERAL UNIVERSITY OF AGRTICULTURE ABEOKUTA NIGERIA(2025-06-25) OLADODU IYANUOLUWAOLUWATOBILOBAABSTRACT This study aims to characterize aquifer systems within a crystalline Basement Complex terrain to enhance groundwater supply for cultivated farmland, using the 1D Electrical Resistivity Method. The investigation was conducted at DUFARMS ASSETRISE LIMITED FARM, located within the Federal University of Agriculture, Abeokuta (FUNAAB), Ogun State, Nigeria, where agriculture is critically dependent on groundwater due to irregular and seasonal rainfall patterns. The geophysical technique adopted was Vertical Electrical Sounding (VES) using the Schlumberger electrode configuration. A total of 24 VES points were surveyed across different sections of the farmland to assess the subsurface lithology and aquifer potential. Field data were processed and interpreted using IP2WIN and WinResist software packages, generating one-dimensional resistivity models for each sounding point. The interpretation revealed a stratified subsurface composed of topsoil, weathered basement, fractured basement zones, and fresh basement rock. The topsoil layer showed resistivity values ranging from 48 to 320 Ω•m, with an average thickness of 0.6 to 2.2 meters, indicating variations in soil composition (sandy, lateritic, or loamy) across the site. Beneath this layer, the weathered basement exhibited resistivity values between 20 and 90 Ω•m, with thicknesses ranging from 3.5 to 15.6 meters—a zone often saturated and serving as a primary aquifer unit. In some locations, fractured basement zones were identified with moderately low resistivity values (typically less than 60 Ω•m), indicating secondary porosity and groundwater storage potential. The dominant curve types encountered include H-type, KH-type, HA-type, and QH-type curves. The H and KH types were most prevalent, indicating a common geoelectric sequence of a relatively resistive topsoil underlain by a more conductive weathered or saturated zone, followed by a resistive fresh basement. These curve types are diagnostic of aquifer-bearing formations within basement terrains. The study identifies the second and third geoelectric layers—corresponding to the weathered and fractured basement zones—as the principal aquiferous units. These layers are potential targets for hand-dug wells, boreholes, or small-scale irrigation schemes. In conclusion, the 1D resistivity method has proven to be a reliable, non-invasive, and cost-effective approach for delineating groundwater-bearing formations in crystalline basement settings. The findings offer valuable guidance for irrigation planning, sustainable water resource management, and borehole siting on the DUFARMS farmland and similar agricultural projects in southwestern Nigeria.Item COMPUTATIONALANALYSISOF CONYECTIVE HEAT AND MASS TRANSFERIN A CASSONNANOFLUID OVER A VERTICAL RIGA PLATE(2025-10-12) TAIWO, MICHAEL ADESOLAABSTRACT The dynamics of heat and mass transport of Cassonnan of luid hasbecomecentreofresearch in recent time due to its scientific and engineering applications in the petrochemical and metallurgical fields. This study examined the combined effects of some thermophysical parameters on Casson nanofluid over a vertical Riga plate. The equations of momentum, energy and mass describing the flow, heat and mass transfer were formulated and transformed into coupled non-linear ordinary differential equations using the similarity transformation method. The resulting self similar problems were solved using spectral collocation method. The impacts of associated pertinent parameters such as Hartmann number (M), Chemical reaction parameter (Cz),Thermal radiation (R),Soret number (Sz),Dufour number (Do), Eckert number (Ec), Prandtl number tPr), Schmidt number (Sc),thermophoretic number (It)ilnd Lewis number (I.n) were presented graphically on Velocity, Temperature and Concentration fields. The Skin frictionCJ!, Nusselt number (Nq) and Sherwood number (Sh) were presented in tabular form.The results showed that variationin the values of modifiedHartmannumber at 1.0 ñ M E 3.0 causedabrupt increase in the velocity profile in the vicinity of the Riga plate wall. The increase in the thermalradiationat 0.0ñRñ1.0andEckert number at 0.10ñEcñ1.12 wereobserved to increase thevelocity, temperature and the thermal condition of the fluid. Various values of Prandtlnumber within the range0.71ñPrE7.0 were foundto decrease the velocity and temperature profiles, indicating that at small values of Prandtl number, the fluid was more conductive while increase in thermal conductivity enhanced the velocity hydrodynamic boundary layer, temperature and thermal boundary layer thickness in the presenceofBrownianmotionparameter{Np)at4.0 ñ M E 12.0.Furthermore, enhancement in fi and Ec improved the Nusselt number which consequently increased the rate of heat transfer while the rate of mass transfer was boosted with various values of Sqand C.Thisstudyrevealed thatthe pertinent parameters improved theflow,heatand mass transport in Casson nanofluid over a vertical Riga plate.Item CONFIGURATION OF THE BASEMENT TOPOGRAPHY OF ABEOKUTA METROPOLIS USING INTEGRATED GEOPHYSICAL METHODS AND MULTI CRITERIA DECISION ANALYSIS (MCDA) FOR GROUNDWATER EXPLORATION(2023-10-30) EDUNJOBI, HAZEEZ OWOLABIABSTRACT A widely distributed and large source of fresh water is groundwater, being a renewable natural source with insubstantial evaporation loss, wide distribution and low risk of contamination, playing very vital roles in the environment and human health. In Abeokuta Metropolis where pipe-borne water is out of reach of many people, groundwater becomes the major source of water supply and its exploration in a basement terrain is faced with complex decisions because of its contradictory alternatives. The research aims to evaluate the basement topography of Abeokuta Metropolis to provide a better understanding of the geological features and hydrological indices that support the flow and distribution of groundwater as well as the accumulation of economic mineral deposits. The Multi Criteria Decision Analysis via Analytic Hierarchy Process (MCDA-AHP) is a mathematical based technique employed to correctly predict groundwater by scaling priorities of influencing parameters to make informed economic decisions. Six groundwater influencing factors; coefficient of anisotropy, lineament density, overburden thickness, aquifer thickness, aquifer resistivity and lithology were integrated to predict groundwater potentials of Odeda, Obafemi Owode, Abeokuta North and Abeokuta South Local Government Areas (LGAs). These parameters were derived from the processing, analysis and interpretation of high resolution aeromagnetic and electrical resistivity data over the study area. The aeromagnetic data was sourced from the Nigerian Geological Survey Agency (NGSA) while the electrical resistivity data was acquired in situ, through Vertical Electrical Sounding (VES) technique; at a spacing interval of 1000 ± 100 m across parts of the LGAs, representing the research location. Qualitative interpretation of high resolution aeromagnetic data revealed magnetic responses ranging from high-moderate-low signatures which characterized the geology of the study area into Basement, transition and sedimentary zones. Continuous filtering of aeromagnetic maps through two-dimensional fast Fourier transform further delineated various geologic boundaries of the magnetic field. Quantitative interpretations were applied to map the depth to magnetic sources and evaluate subsurface linear structures referred to as lineaments. Spectral Analysis Technique (SAT), Source Parameters Imaging (SPI) and 3D Euler deconvolution method revealed depth range of 99-340, 133-294 and 150-250 m respectively. These depth results confirmed the presence of near surface intrusive rock minerals like kaolin, feldspar, quartzite, among others. Evaluation of lineaments by CET grid analysis showed the study area to be composed of linear structures predicted to be faults, cracks, fractures, voids and cracks, and their NE-SW orientation is in conformity with the Pan African Orogeny. Interpretation of one hundred and forty four VES data aided computations of hydrogeological parameters and mapping of lithological units. Lateritic sequence, sandstones, clay, continental sands, kaolin deposits and Basement rocks that are granitic or magmatic in nature are the lithological units mapped. The integration of all the groundwater influencing factors using GIS produced a model map that is graded into very low, low, high and very high potentials. Evaluation of the basement topography has demonstrated strong reliability in groundwater potential modelling and it is recommended that the results of this research should be adopted as an information framework in making wise investments in Abeokuta Metropolis.Item D'RUMINANT: A SUSTAINABLE SOLUTION TO ENHANCING DATA INTEGRITY, BOOSTING FARM EFFICIENCY AND ANIMAL WELL-BEING(2024-09-15) AWUNOR SAMUEL EMEKE
